University of Bahrain
Scientific Journals

Optimized and validated spectrophotometric method for the determination of palladium(II) in synthetic mixture and automobile workshop area samples

Show simple item record

dc.contributor.author Azmi, Syed Najmul Hejaz
dc.contributor.author Iqbal, Bashir
dc.contributor.author Al Ruqishi, Badriya Humaid Khamis
dc.contributor.author Al Sayabi, Safa Ali Mohammed
dc.contributor.author Al Quraini, Nawal Musbih Khaif
dc.contributor.author Rahman, Nafisur
dc.date.accessioned 2018-07-29T10:32:13Z
dc.date.available 2018-07-29T10:32:13Z
dc.date.issued 2016
dc.identifier.issn 1815-3852
dc.identifier.uri https://journal.uob.edu.bh:443/handle/123456789/1107
dc.description.abstract An optimized and validated spectrophotometric method has been developed for the determination of Pd(II) in synthetic mixture and automobile workshop area samples. The method was based on the complex formation of Pd(II) with cefixime in methanol-distilled water medium in the presence of Na2HPO4-citric acid buffer solution of pH 2.6 at room temperature. The complex showed the maximum absorption wavelength at 352 nm. Beer’s law was obeyed in the working concentration range of 0.7502–16.5004 lg mL1 with apparent molar absorptivity of 1.224 · 104 L mol1 cm1 and Sandell’s sensitivity of 0.002 lg/cm2 /0.001 absorbance unit. Limits of detection (LOD) and quantitation (LOQ) for the proposed method were 0.07 and 0.21 lg mL1 , respectively. The effect of diverse ions such as Cu(II), Mg(II), Mn(II), Ca(II), Fe(II), Cr(III), Ni(II), Al(III), Fe(III), Cd(II) and Zn(II) has been studied in the presence of Pd(II) and the maximum tolerance limit of each metal was calculated. The proposed method was successfully applied for the determination of Pd(II) in synthetic mixture and automobile workshop area samples. ª en_US
dc.language.iso en en_US
dc.publisher University of Bahrain en_US
dc.rights Attribution-NonCommercial-ShareAlike 4.0 International *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/4.0/ *
dc.subject Palladium (II)
dc.subject Spectrophotometric determination
dc.subject Environmental samples
dc.subject Validation
dc.title Optimized and validated spectrophotometric method for the determination of palladium(II) in synthetic mixture and automobile workshop area samples en_US
dc.type Article en_US
dc.source.title Arab Journal of Basic and Applied Sciences
dc.abbreviatedsourcetitle AJBAS